Understanding Occupancy Classification in Building Design

Understanding Occupancy Classification in Building Design

Determining the occupancy classification is one of the first steps when designing a building or structure. This classification refers to the primary use or purpose of the building or specific portions of it. Occupancy classification impacts critical safety and design factors, including fire protection, structural load requirements, and building height or area limitations. Architects and engineers must fully understand occupancy classification to ensure compliance with building codes and occupant safety.

2021 IBC

Buildings may fall under a single occupancy classification or include multiple types. Mixed-use buildings, which house different occupancies, follow unique rules based on varying risk levels. Careful consideration of these classifications is essential to accurately categorize spaces and ensure code compliance.

Tips for Analyzing Occupancy Classification

Focus on the primary use of each space when analyzing a building’s occupancy classification. Support areas, such as restrooms, mechanical rooms, and storage closets, typically follow the primary classification unless specific criteria define them as incidental occupancies. For instance, a boiler room exceeding 15 psi and 10 horsepower qualifies as an incidental occupancy.

Types of Mixed-Use Occupancies

1. Accessory Occupancies

Accessory occupancies are spaces supporting the main building function without requiring separate classification.

  • Key Considerations:
    • Building area limitations follow the main occupancy’s classification.
    • Accessory spaces cannot exceed 10% of a story’s area.
    • No fire separation is needed between accessory and primary spaces.
    • Newer codes allow small storage areas to follow the primary occupancy classification.
  • Helpful Tip: Small assembly spaces under 750 square feet or fewer than 50 occupants may qualify as a B occupancy.

2. Nonseparated Occupancies

Nonseparated occupancies exist when multiple occupancy types share a building without fire separation.

  • Key Considerations:
    • The most stringent building height and area requirements apply.
    • Fire suppression provisions cover the entire building.
    • No fire separation is required between different occupancies.

3. Separated Occupancies

Separated occupancies require fire barriers or horizontal assemblies to divide different occupancy types.

  • Key Considerations:
    • Each occupancy follows its own height and area limits.
    • Building area calculations are summed as the ratios of each occupancy’s area to its allowable area.
    • Fire separation ratings depend on Table 508.4 of the 2018 IBC.

Choosing Separated vs. Nonseparated Occupancies

Selecting separated or nonseparated occupancies depends on the project’s requirements. Nonseparated occupancies are simpler and cost-effective but may demand sprinklers. Separated occupancies allow design flexibility, such as avoiding sprinkler installation by using fire-rated walls.

Example: A project might avoid sprinklers using separated occupancies but require them with nonseparated classifications. Evaluate client goals to determine the best approach.

Project-Specific Considerations

Every building presents unique challenges, and occupancy classification significantly shapes the final design. When selecting classifications, consider factors such as:

  • Sprinklers: Are they necessary for fire safety under one option but not another?
  • Building Height and Area: How do size limitations differ?
  • Open Spaces: Will fire separation walls interfere with open, interconnected areas?

By carefully evaluating these considerations, architects can balance safety, compliance, and design goals effectively.

Final Thoughts

Occupancy classification plays a vital role in building design, particularly for mixed-use structures. By understanding Occupancy Classification in Building Design and the interaction of spaces and their classifications, architects can create safer, functional, and visually appealing designs. EVstudio’s expertise ensures that every project meets code requirements while addressing the unique needs of its clients.